1-touch for HP-UX安装配置操作手册 联系客服

发布时间 : 星期一 文章1-touch for HP-UX安装配置操作手册更新完毕开始阅读ae41e8c2aa00b52acfc7ca91

1-touch for HP-UX安装配置操作手册

Excessive Collisions = 0 Internal MAC Transmit Errors = 0 Carrier Sense Errors = 0 Frames Too Long = 0 Internal MAC Receive Errors = 0

LAN Interface test mode. LAN Interface PPA Number = 1

clear = Clear statistics registers

display = Display LAN Interface status and statistics registers end = End LAN Interface Administration, return to Test Selection menu = Display this menu

ppa = PPA Number of the LAN Interface

quit = Terminate the Administration, return to shell reset = Reset LAN Interface to execute its selftest specific = Go to Driver specific menu

Enter command: quit quit

1.3.9 INSTALL/UNINSTALL IGNITE软件 备注:在HP-UX上布署1-touch,要求客户端和1-touch的Ignite版本相同,如果不同的话,可以从HP网站上免费下载最新的Ignite版本安装在HP-UX操作系统上;(无须重新启动主机) 关于安装更新Ignite的详细信息,请参考:

http://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c01942666/c01942666.pdf

1-touch for HP-UX安装配置操作手册

1.3.10 IGNITE详细信息介绍

关于Ignite的相关原理介绍,HP文档网站上提供了很详细的中文说明,具体请参考HP网站,或者以google中以关键字<>来查询,详细的信息尽在其中;

第二章 开始安装

2.1 涉及主机及安装模块要求

本次备份恢复共涉及到4台机器,CS主机、1-touch Server,HP-UX客户端,恢复用目标主机; 在此文档中涉及将HP-UX客户端备份出来的操作系统等信息通过CommVault 1-touch server异机恢复到另外一台同构CPU的HP-UX主机;

在此次测试环境中,具体的主机列表及其它信息如下:

角色 CS 1-touch server 操作系统 Windows2003sp2 HP-UX 11.31 (ia64) HP-UX 11.31 (ia64) N/A (ia64) 主机名 xj-comvault hisdbbk cv-clientname xj-comvault cv_hiskdbbk 安装软件 commserve 1、1-Touch Boot Server Agent 2、Media Agent 3、igniter-server(HP software) 1、FileSystem IDA 2、Igniter-client(HP software) 恢复前:N/A 源客户端 目标主机 APP66A4A 恢复前:N/A Cv_APP66A4A 恢复前:N/A 2.2 1-TOUCH SERVER模块安装

前提:在安装1-touch Server Agent之前,请提前确认Ignite软件工作正常 ;

1) 进入到CommVault软件安装目录,并运行cvpkgadd命令

hisdbbk[/commvault/hp]./cvpkgadd

2) 选择接受软件许可协议,并根据需要选择相应的模块, 并根据提示安装完成;

Select the Simpana module that you would like to install.

1) Proxy FileSystem IDA 2) Oracle IDA

3) Oracle SAP IDA 4) SAPMAXDB IDA 5) Sybase IDA 6) DB2 IDA

7) Data Archiver for UNIX

1-touch for HP-UX安装配置操作手册

8) Quick Recovery Agent

9) 1-Touch Boot Server Agent 10) Recovery Director for UNIX 11) SRM File System Agent 12) Exit

Module number: [1] 9

3) 通过CommServe主机推送最新的Service Pack补丁;

2.3 1-TOUCH客户端软件安装

前提:在安装之前,请提前确认Ignite软件工作正常 ;

1) 进入到CommVault软件安装目录,并运行cvpkgadd命令

hisdbbk[/commvault/hp]./cvpkgadd

2) 选择接受软件许可协议,并根据需要选择相应的模块,并根据提示安装完成;

Select the Simpana module that you would like to install.

1) Media Agent 2) FileSystem IDA 3) Proxy FileSystem IDA 4) Oracle IDA 5) Oracle SAP IDA 6) SAPMAXDB IDA 7) Sybase IDA 8) DB2 IDA

9) Data Archiver for UNIX 10) Quick Recovery Agent 11) 1-Touch Boot Server Agent 12) Recovery Director for UNIX 13) SRM File System Agent 14) Exit

1-touch for HP-UX安装配置操作手册

Module number: [1] 2

3) 通过CommServe主机推送最新的Service Pack补丁;

第三章 备份篇 3.1 系统备份前检查工作

在进行系统备份前,需要确认在1-touch服务器和HP-UX客户端上Ignite相关的NFS服务是否正常工作;同时,还得检查dfstab是否已经将client相关的目录mount起来。具体如下:

1) 查看dfs文件配置

hisdbbk[/var/opt/ignite/clients]cat /etc/dfs/dfstab 查看dfstab文件 # place share(1M) commands here for automatic execution # on entering init state 3. #

# share [-F fstype] [ -o options] [-d \# .e.g,

# share -F nfs -o rw=engineering -d \share -F nfs -o anon=2 /var/opt/ignite/clients

2) 重新启动1-touch server上NFS服务;(注意:如果1-touch服务器有其它应用程序使用NFS,请提前

确认) (注意启动服务的顺序)

APP66A4A[/]cd /sbin/init.d

APP66A4A[/sbin/init.d]./nfs.client stop killing nfs4cbd

APP66A4A[/sbin/init.d]./nfs.server stop killing nfsd killing rpc.mountd

APP66A4A[/sbin/init.d]./nfs.core stop killing nfsmapid killing rpcbind